Woodio Logo

WOODIO FLUSH DOORS

ISI STANDARD PERFORMANCE CERTIFICATE

IS : 2202 (Pt-I) : 1999
S. No. Test Parameter Units Requirement as per IS:2202(Pt-I):1999 Observed Value Flush Doors
1 Dimensions mm
Length mm ± 5 mm 1.5
Width mm ± 5 mm 0
Thickness mm ± 1 mm 0.12
Squareness mm Variation in thickness between any two points not more than 0.8 mm 0.55
2 General Flatness mm Deviation not more than 1 mm per 500 mm length 0.4
3 Local Planeness mm Twist, cupping & warping not greater than 6 mm 3
4 End Immersion Test Depth of deviation not greater than 0.5 mm 0.15
5 Glue Adhesion Test No delamination Confirms
6 Knife Test No delamination Confirms
7 Impact Indentation mm Minimum pass standard Excellent
No cracking, tearing or delamination Confirms
Depth of indentation not greater than 0.2 mm 0.14
8 Slamming No visible damage after 50 drops Confirms
9 Flexure (Deflection) mm Deflection at maximum load not greater than
15 mins after loading 50 Kg 1/30 of length & 1/15 of width, whichever is less 55.62
3 mins after load removal mm Residual deflection not greater than 1/10 of maximum deflection 2.44
10 Shock Resistance
Soft and light body impact No visible damage Confirms
Soft and heavy body impact No visible damage Confirms
11 Buckling (Deflection in mm) No deterioration Confirms
After 5 mins of 40 Kg loading Initial deflection not greater than 50 mm 43.72
15 mins after load removal Residual deflection after 15 minutes of unloading not greater than 5 mm 3.17
12 Edge Loading (Deflection)
After 15 mins of 100 kgs loading mm Deflection at max. load not greater than 5 mm 3.18
3 mins after load removal mm Residual deflection after removal of load not greater than 0.5 mm 0.35
Lateral buckling Not more than 2 mm during loading 1.22
Residual lateral buckling No residual lateral buckling after load removal Confirms
13 Screw Withdrawal Strength N Not less than 1,000 2,000
Surface condition: no visible damage to the surface either by delamination or extra chipping off at the points of withdrawal Confirms
14 Varying Humidity Test No visible warping, twisting or delamination Confirms
Maximum departure from the general planeness not more than 1 mm 0.47
Recovery – At least 90% of the change in dimension 99.02
15 Misuse No permanent deterioration of the fixing or any other part of the door set in hindering its normal working after test Confirms